Skip to main content
. 2020 Sep 28;164:114054. doi: 10.1016/j.eswa.2020.114054

Table 7.

Results using additional COVID-19 chest X-ray images.

Method Accuracy (%) Sensitivity (%) Specificity (%) F1 score (%) AUC
ResNet50 Features + SVM 95.79 94.00 97.78 95.92 0.9987
Fine-tuning of ResNet50 92.63 88.00 97.78 92.63 0.9973
End-to-end training of CNN 90.53 88.00 93.33 90.72 0.9920
BSIF + SVM 91.58 90.00 93.33 91.84 0.9933