Skip to main content
. 2020 Sep 17;9(9):525–538. doi: 10.1089/wound.2019.1112

Figure 5.

Figure 5.

(A) The 46-year-old man with previous fasciotomy initially closed with split-thickness skin grafting 5 years postclosure, presented for options to address painful, tethered skin grafts. The skin graft was excised and the CETE device was placed. Image shows immediate postoperative appearance of CETE in combination with NPWT. (B) Wound after tissue expansion and delayed closure. Image courtesy of I.L.V. NPWT, negative-pressure wound therapy.