Table 3.

Diagnostic sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detection of Gleason Score ≥ 7 tumor were calculated for PI-RADS version 2.0 and 2.1.

PZ TZ
PI-RADS v2.0 (%) PI-RADS v2.1 (%) p value PI-RADS v2.0 (%) PI-RADS v2.1 (%) p value
Sensitivity 95.4 94.3 1.00 95.8 93.8 1.00
Specificity 31.2 24.2 0.10 53.7 42.1 0.03*
PPV 48.8 46.1 0.61 51.1 45.0 0.40
NPV 90.9 86.1 0.51 96.2 93.0 0.50

PI-RADS assessment categories were dichotomized using a predefined cut-off value: a PI-RADS category of ≥ 3 was defined as positive. Specificity in the TZ was significantly lower for PI-RADS version 2.1. All other diagnostic values did not differ significantly. *Results were declared to be significant if p < 5%.