Skip to main content
. 2020 Sep 29;20:427. doi: 10.1186/s12872-020-01711-x

Table 4.

Hazard ratios for recurrent AF after catheter ablation according to CRP cut-off value of 3 mg/l

Variable CRP level, mg/l
<  3a ≥ 3
Events/Patients 181/551 66/160
Incidence, %b 36.9 53.8
 95% CI 31.6–43.2 41.6–69.6
Hazard ratio unadjusted 1.0 1.45
 95% CI 1.09–1.92
P value 0.010
Hazard ratio adjusted for age and sex 1.0 1.41
 95% CI 1.06–1.88
P value 0.017
Hazard ratio adjusted for age and sex + additional factors 1.0 1.44
 95% CI 1.06–1.95
P value 0.019

Models adjusted for additional factors controlled for body mass index, AF type (paroxysmal vs. persistent), history of hypertension (yes vs. no), history of heart failure (yes vs. no), history of obstructive sleep apnea (yes vs. no), duration of AF (years), and LAD

Multivariable model included n = 659 patients

aCRP group < 3 mg/l served as reference for each comparison

bIncidence at 1 year of follow-up in percent