Table 2.

Root Mean Squared Error (RMSE) for the x and y displacements (Ux, Uy) calculated over each sequence

Methods Synthetic In Vivo
Ux (mm) Uy (mm) Ux (mm) Uy (mm)
FFD 2.06±1.01 1.88±0.43 2.58±1.48 2.86±1.22
FNT 0.67±0.14 0.75±0.16 1.07±0.27 1.64±0.53
Motion Only 1.41±0.32 1.57±0.24 2.45±0.76 2.37±0.73