Skip to main content
. 2020 Oct;217:107960. doi: 10.1016/j.exppara.2020.107960

Table 1.

Primer sequences for the LAMP assays specific for Dracunculus medinensis, D. insignis and the copepod internal positive control.

Primer Sequence (5′–3′)
D.med F3 GTTATTACTTCTCATGCTATTATGATA
D.med B3 AAACTAAAAATAGCCAAATCAACTCTAT
D.med FIP ACAGGCATCAATCAATAACTAACATTATTCTGGTAATGCCTAGTTTGATTGGA
D.med BIP AATATTGATTTTGTCTGCTTGTTTGGTGCCAGGATGACCCCTAGTACTT
D.med F-loop ATATCAGGAGCCCCCAACATT
D.med B-loop
TCTTGTGGAACTAGATGGACTA
D.insig F3 TTTTTATGGTTATGCCTAGTTTGATT
D.insig B3 CAGAACAATGTAAACTAAAAATAGCCA
D.insig FIP CATCAAAGAAACAGGTATTAACCAATAACGGTGGTTTTGGTAATTGGATAGTT
D.insig BIP AGTCGATAGTTCTTGTGGTACTAGTTCAACACTATTTCCAGGATGACCA
D.insig F-loop CACATTATTCAAACGAGGAAAACTT
D.insig B-loop
GAACTGTTTATCCTCCTTTGAGT
Copepod F3 GTCGACTGTGGCATAGACG
Copepod B3 CTCATTCCGATTACCAGGCC
Copepod FIP TCAGGCTCCCTCTCCGGAATCCCACAGTGGTTTTGACGG
Copepod BIP AAGGCAGCAGGCACGCAAATTCGGATGAGTCTGGTATCGT
Copepod F-loop CGAACCCTAATTCCCCGTTAC
Copepod B-loop GCCGAGGTAGTGACGAAAAAT