Skip to main content
. 2020 Sep 30;15(9):e0239943. doi: 10.1371/journal.pone.0239943

Table 1. Summary of detection rules studied.

B1 is the the attenuation duration below threshold t1, B2 is the attenuation duration between t1 and t2, B3 is the attenuation duration below t2.

App Detection Rule Parameter Values
Swiss App B1 + 0.5B2 > 15 mins t1 = 50db, t2 = 55dB
German App B1 + 0.5B2 > 10 mins t1 = 55db, t2 = 63dB
Italian App B3 > 15 mins t2 = 73dB