Skip to main content
. 2020 Sep 11;46(10):1803–1851. doi: 10.1007/s00134-020-06198-w

Table 22.

Electroencephalogram (EEG). Background. Isoelectric (1)

Author, year Sample size, n Timing Timing outcome TP FP FN TN Sensitivity % [95% CI] FPR % [95% CI]
Scarpino, 2020 [69] 218 12 h 6 mo 17 0 115 86 12.9 [7.7–19.8] 0 [0–3.4]
Scarpino, 2020 [69] 240 72 h 6 mo 12 0 154 74 7.2 [3.8–12.3] 0 [0–4]

(1) Defined as EEG amplitude < 2 µV