Table 2.
Comparison between pure position control and impedance control.
| Control mode | Stability | Position steady-state error (deg) | Peak current (A) | Compliance |
|---|---|---|---|---|
| Impedance control | Stable | 11.4 | 4.309 | Soft |
| Position control | Unstable | — | 11.03 | Hard |
Comparison between pure position control and impedance control.
| Control mode | Stability | Position steady-state error (deg) | Peak current (A) | Compliance |
|---|---|---|---|---|
| Impedance control | Stable | 11.4 | 4.309 | Soft |
| Position control | Unstable | — | 11.03 | Hard |