Skip to main content
. 2020 Oct 1;10:16339. doi: 10.1038/s41598-020-73261-3

Table 1.

Melt-spun PLLA/BaTiO3 fibre labels with drawing conditions, fibre diameters.

Label BaTiO3, wt% Draw ratio Draw temperature, (°C) Fibre diameter, (µm) ± STDV
P1 0 1 22.4 ± 0.80
B1 3 1 24.1 ± 0.77
DR2 3 2 120 15.7 ± 0.60
DR3 3 3 120 13.3 ± 0.47
DR3.5 3 3.5 120 12.6 ± 0.58
T90 3 3 90 13.9 ± 0.54
T100 3 3 100 13.2 ± 0.82
T110 3 3 110 12.9 ± 0.54
T120 3 3 120 13.3 ± 0.47
T130 3 3 130 13.0 ± 0.44