Skip to main content
. 2020 Oct 1;10:16331. doi: 10.1038/s41598-020-73060-w

Table 4.

Comparison of performance of the proposed algorithm versus other.

Accuracy
State-of-art algorithm28 (based on Fig. 7) Proposed method (for CNN-dig)
Normal 0.82 0.96
AF 0.92 0.98
I-AVB 0.78 0.99
LBBB 0.85 1.00
RBBB 0.96 0.99
PAC 0.74 0.92
PVC 0.87 0.92
STD 0.77 0.90
STE 0.50 0.98
Average accuracy 0.80 0.96

AF Atrial fibrillation, I-AVB first-degree atrioventricular block, LBBB left bundle branch block, RBBB right bundle branch block, PAC premature atrial contraction, PVC premature ventricular contraction, STD ST-segment depression, STE ST-segment elevation.