Skip to main content
. 2019 Jul 2;10(1):24–33. doi: 10.2478/joeb-2019-0004

Table 1.

List of all variables used for comparing different varieties of the bioimpedance input data and hyperparameters in the machine learning for prediction of ischemic duration.

Variable Description Tested levels Values
Measurement noise Setting for simulated input data 3 0, 10, 30
Liver variance Setting for simulated input data 2 5, 20
Drift Setting for simulated input data 3 0 ±50 +100
Frequencies Selection of input variables 3 {102 104 106}, 101:7, 101:0.1:7
Sample size Training and testing data size 2 20, 100
Regularization Neural network hyperparameter 3 10-1, 10-2, 10-3
Hidden layer size Neural network hyperparameter 3 2, 5, 25
Minibatch size Neural network hyperparameter 2 16, 32
Epochs Neural network hyperparameter 2 250, 500