Table 2.
Comparison of Vessel Metrics With High Resolution and High-Speed Acquisition Protocols
| High Resolution | High Speed | P Value | |
|---|---|---|---|
| SCP VD | 32.18 ± 2.80 | 33.07 ± 2.86 | <0.0001 |
| SCP VLD | 8.30 ± 0.53 | 7.38 ± 0.30 | <0.0001 |
| DCP VD | 26.47 ± 5.09 | 27.75 ± 4.25 | <0.0001 |
| DCP VLD | 10.88 ± 0.97 | 9.62 ± 0.82 | <0.0001 |
| CC FD entire slab | 34.77 ± 7.06 | 31.72 ± 7.57 | 0.004 |
| CC FD nasal | 34.51 ± 6.88 | 31.61 ± 8.04 | 0.008 |
| CC FD temporal | 35.04 ± 7.71 | 31.84 ± 7.88 | 0.004 |
Student's t-test for paired samples and Wilcoxon signed-rank test were performed to compare high resolution and high-speed modes. CC, choriocapillaris; CI, confidence interval; DCP, deep capillary plexus; FD, flow deficit; SCP, superficial capillary plexus; VD, vessel density; VLD, vessel length density.