Skip to main content
. 2020 Sep 17;89(7):1810–1817. doi: 10.1038/s41390-020-01159-x

Table 3.

Variability of neural breathing pattern during mechanical ventilation weaning.

MV (n = 13) ETT-CPAP (n = 13) P value
Breath area (μV·s)
  SDArea 312 [209–415] 326 [230–458] 0.040
  SDSDArea 402 [221–468] 424 [287–549] 0.021
  TIArea 4.08 [3.39–5.49] 5.00 [3.58–7.38] 0.033
Neural Ti (s)
  CVNTi 0.74 [0.52–0.87] 0.48 [0.42–0.55] 0.046
Breath amplitude (μV)
  SDSDAmp 7.57 [5.52–9.43] 9.50 [6.45–10.74] 0.013
Breath width (s)
  SDWidth 0.15 [0.12–0.23] 0.11 [0.11–0.15] 0.033
  CVWidth 0.37 [0.32–0.50] 0.34 [0.28–0.37] 0.046
  SDSDWidth 0.19 [0.15–0.31] 0.16 [0.14–0.21] 0.040

MV mechanical ventilation, ETT-CPAP endotracheal continuous positive airway pressure, Ti inspiratory time, Te expiratory time.

Results are expressed as median [IQR]; statistical analysis was performed by using the Wilcoxon’s signed-rank test.