TABLE.

Summary of Literature Using Ultraviolet Germicidal Irradiation for Filtering Face Respirators Decontamination

First Author Year Dose Time Dose Repeated Total Accumulated Dose Distance Bulb Specs Effectiveness Room Conditions Fit/Degradation
Tseng10 2007   5–255 sec 2.51–6.50 mJ/cm2 2.51–6.50 mJ/cm2 30.5cm 4 × 8 W Kills 99%, decreased effectiveness at higher humidity 21–28°C, 55% & 85% RH  
Viscusi29 2009 0.18–0.20 mW/cm2 15 min/side 324–360 mJ/cm2 0.97–1.08 J/cm2   40W   21°C, 50% RH No observable physical changes, filtration performance not affected, no noticeable changes in airflow resistance
Bergman36 2010 1.8 mW/cm2 15 min 1.62 J/cm2 4.86 J/cm2 25 cm 40 W   21°C, 50% RH No observable physical changes, no significant change in penetration
Heimbuch33 2011 1.6–2.2 mW/cm2 15 min 1.44–1.98 J/cm2 1.44–1.98 J/cm2 25 cm 80 W >4 log reduction   Effective decontamination against droplet and aerosolized influenza challenge, no change to fit after decontamination
Bergman35 2011 1.6–2.0 mW/cm2 15 min 1.44–1.98 J/cm2 4.32–5.94 J/cm2   40 W >4 log reduction 21°C, 50% RH Fit not significantly affected after 4 fit tests, no degradation
Viscusi34 2011 1.6–2.0 mW/cm2 15 min/side 2.88–3.96 J/cm2 2.88–3.96 J/cm2   40 W   21°C, 50% RH No changes in fit, odor detection, comfort, or donning difficulty with UVGI- masks were redonned 5×
Lore37 2012 1.6–2.2 mW/cm2 15 min 1.44–1.98 J/cm2 4.32–5.94 J/cm2 25 cm 2 × 15 W >4 log reduction   Decontamination methods did not significantly degrade filter performance at 300 nm particle size
Lindsley38 2015   n/a 120–950 J/cm2 120–950 J/cm2 6.2 cm 2 × 15 W   27°C, 25% RH No significance change in flow resistance, decreased penetration strength and strap breaking strength at very high exposure
Mills11 2018   60–70 sec 1.1 J/cm2 1.1 J/cm2 1 m 8 × 0.39 W/cm2 >3 mean log reduction, straps less effectively decontaminated 21°C, 50% RH Masks oversaturated with virus in physiologically relevant solvents sebum and mucin, ultraviolet germicidal irradiation levels fully decontaminated masks, statistically significant reduction in virus viability
Heimbuch12 2019 16–18 mW/cm2 60–70 sec 1.0–1.2 J/cm2 20× 20 J/cm2 1 m 8 × 0.39 W/cm2 >3 mean log reduction, straps less effectively decontaminated, tested on SARS-CoV-1 22.5°C No meaningfully significant effect on fit, air flow resistance, or particle penetration for 15 models tested, some models had significant effects due to donning/doffing cycles
Card42 2020 0.1 mW/cm2 20 min/side 240 mJ/cm2     60.6 cm 30 W      
Lowe9 2020 0.2 mW/cm2 5–6 min 300 mJ/cm2     10 ft 16x      

Abbreviations: J, Joules; mJ, milliJoules; mW, milliwatts; RH, relative humidity; W, watts.