Table 3.
No. | Name | Probe | Oxidation product | Comment | References | ||||
---|---|---|---|---|---|---|---|---|---|
λabs (nm) | ε (M−1cm−1) | λem (nm); ϕ | λexc (nm) | ε (M−1cm−1) | λem (nm); ϕ | ||||
74 | MitoPY1 | 489a 510a |
14,300a 14,200a |
540; 0.019a | 510a | 22,300 | 528, 0.405a | k(H2O2) ≈ 0.201 M−1s−1 | Dickinson and Chang, 2008 |
75 | MitoB, m-MitoPhB(OH)2 | - | - | - | HPLC detection: λAbs = 268 nm or LC-MS detectionr; k(H2O2) ≈ 3.8 M−1s−1b k(ONOO−) = 1 ×106 M−1s−1 |
Cochemé et al., 2011 Sikora et al., 2013 |
|||
76 | o-MitoPhB(OH)2 | - | - | - | HPLC detection: λAbs = 268 nm or LC-MS detectionr; k(ONOO−) = 3.5 × 105 M−1s−1 |
Sikora et al., 2013 | |||
77 | p-MitoPhB(OH)2 | - | - | - | HPLC detection: λAbs = 268 nm or LC-MS detection; k(ONOO−) = 1 × 106 M−1s−1 |
Sikora et al., 2013 | |||
78 | SHP-Mito | 342d | 17,000d | 470; 0.13d | 383d | 15,000d | 545; 0.12d | Ratiometric probe; Two-photon probe; k(H2O2) ≈ 1.0–1.2 M−1s−1d |
Masanta et al., 2012 |
79 | Mito-H2O2 | 490e | 527; 0.003e | 376e | 527e | Increase in fl. intensity | Xu J. et al., 2016 | ||
80 | MI-H2O2 | 425f | 0.0087f | 525f | 555; 0.11f | k(H2O2) ≈ 4.35 M−1s−1f | Xiao et al., 2016 | ||
81 | CBZ-H2O2 | 340g | ca. 400g | 350g | 430g | Zhang K. et al., 2016 | |||
82 | 507h | 0.002h | 495h | 515; 0.213h | Probe designed for HOCl detection | Li G. et al., 2017 | |||
83 | HKB | 564i | 666i | 440i | 594i | Ratiometric probe; k(H2O2) ≈ 1.07 M−1s−1i |
He et al., 2018 | ||
84 | HBTPB | 312j | 539j | 373j | 669j | Ratiometric probe; ESIPT-based probe | Tang et al., 2018 | ||
85 | 500k | 640k | 500k | 535k | Ratiometric probe | Shen et al., 2018 | |||
86 | pep3-NP1 | 352 455l |
9020 10,700l |
646; 0.033l | 455l | 555; 0.058l |
k(H2O2) ≈ 0.487 M−1s−1l; DNA-binding probe |
Wen et al., 2015 | |
87 | Mito-HP | 358m | 543m | 446m | 543m | Increase in fl. intensity | Dai et al., 2018 | ||
88 | Mito-NP | 360n | 460n | 553n | ICT-based probe; k(H2O2) ≈ 3.5 M−1s−1 |
Liang et al., 2019 | |||
89 | MBTBE | 380o | 0.018o | 520o | 569; 0.097o | Shu et al., 2020b | |||
90 | CM | 400p | 340p | ca. 450p | Ratiometric probe | Weber et al., 2020 | |||
91 | Mito-HT | 380q | 493; 0.39q | 395q | 562; 0.43q | Ratiometric probe | Wang C. et al., 2020 |
20 mM HEPES, pH 7, 25°C.
KCl medium, pH 8.0, 25°C.
50 mM phosphate buffer, pH 7.4, 1 M CH3OH, RT.
30 mM MOPS, 100 mM KCl, pH 7.4.
20 mM phosphate buffer, pH 7.4, 1% DMSO, 25°C.
10 mM PBS, pH 8.0.
20 mM PBS, pH 7.4, 20% DMSO.
20 mM PBS, pH 7.4, 1% DMSO.
10 mM PBS, pH 7.0, 30% CH3CN.
10 mM HEPES/CH3CN (1/1, v/v), pH 7.4.
PBS/CH3CN, (1/9, v/v), pH 7.4.
Tris-HCl, pH 7.2, 1% DMSO.
10 mM PBS, pH 7.4, RT.
20 mM PBS, pH 7.4.
PBS : C2H5OH, 7:3, pH 7.4.
PBS/CH3OH (52%), pH 7.4.
0.01 M PBS/DMSO (5/1, v/v), pH 7.4.