Diameter, weight, maximum tensile strength, and static water contact angle of sutures.

Suture Diameter (mm) Weight (mg) Maximum tensile strength (N) Static water contact angle (degree)
Noncoated 0.60 ± 0.01 0.36 ± 0.03 170 ± 3 38 ± 6
PMB-coated 0.61 ± 0.00 0.36 ± 0.05 170 ± 4 31 ± 5∗∗