Linearity under dilution for the automated measurement of adenosine deaminase isoenzyme 2 (ADA2). Results were obtained from two pools of serum from dogs and pigs and two pools of saliva from dogs, horses, pigs and cows with high and low ADA2 activity

Species Sample ADA2 (IU/L) Slope Y-intercept R2 P
Dog Saliva 3.90 1.14 ± 0.07 −0.04 ± 0.08 0.98 < 0.001
0.64 1.35 ± 0.15 −0.02 ± 0.03 0.95 < 0.001
Serum 1.79 1.14 ± 0.10 −0.01 ± 0.05 0.95 < 0.001
0.98 1.16 ± 0.14 −0.01 ± 0.05 0.94 < 0.01
Horse Saliva 4.77 1.00 ± 0.12 −0.15 ± ± 0.17 0.91 < 0.001
0.66 1.02 ± 0.05 0.05 ± 0.04 0.99 < 0.001
Pig Saliva 6.06 1.02 ± 0.03 0.00 ± 0.05 0.99 < 0.001
0.67 1.04 ± 0.13 −0.04 ± 0.04 0.92 < 0.001
Serum 4.30 1.38 ± 0.06 −0.35 ± 0.07 0.99 < 0.001
0.91 1.34 ± 0.13 −0.21 ± 0.06 0.95 < 0.001
Cow Saliva 2.20 1.65 ± 0.14 0.06 ± 0.09 0.96 < 0.001
0.56 1.41 ± 0.21 −0.05 ± 0.04 0.92 < 0.01