Table 5.

Comparison of differences between pre- and post-treatment in performed CXL protocols. Significance is marked in italics

Parameter Difference of
S-CXL (3*30)
Difference of
A-CXL (9*10)
Difference of
A-CXL (18*5)
P value
(3*30–9*10)
P value
(3*30–18*5)
P value
(9*10–18*5)
CVS-IOP [mmHg] + 2.97 ± 0.76 + 2.03 ± 0.79 + 1.14 ± 1.04 0.006 0.000 0.011
CVS-CT [μm] − 56.83 ± 55.13 − 25.06 ± 58.8 − 43.17 ± 25.43 0.169 1.000 0.812
A1 velocity [m/s] − 0.02 ± 0.01 − 0.01 ± 0.01 − 0.01 ± 0.01 0.973 0.258 1.000
Deflection Amp [mm] − 0.17 ± 0.04 − 0.14 ± 0.05 − 0.09 ± 0.09 0.575 0.001 0.042
DA ratio 2 mm [mm] + 0.31 ± 0.16 + 0.09 ± 0.23 + 0.19 ± 0.23 0.009 0.287 0.496
Integrated radius [mm^-1] − 0.83 ± 0.36 − 0.74 ± 0.36 − 0.59 ± 0.55 1.000 0.344 0.912
SP A1 [mmHg/mm] + 24.66 ± 9.27 + 17.81 ± 10.07 + 8.08 ± 8.78 0.100 0.000 0.009
Kc[mean] [N/m] + 13.46 ± 18.63 + 13.7 ± 8.64 + 6.7 ± 11.42 1.000 0.423 0.383
Kc[linear] [N/m] + 12.23 ± 15.83 + 12.64 ± 6.45 + 6.26 ± 10.25 1.000 0.376 0.306

A-CXL accelerated CXL, A1 applanation 1, adj adjusted, Amp amplitude, CT corneal thickness measured by Corvis ST, CVS Corvis ST, CVS-IOP uncorrected Corvis ST IOP, CXL corneal cross-linking, IOP intraocular pressure, DA deformation amplitude, Kc corneal stiffness derived from waveform analysis, S-CXL standard CXL, SE standard error, SP A1 stiffness parameter at 1st applanation