Table 1.

MR scan parameters

T1WI* T2WI FLAIR MPRAGE**
Sequence 2D FSE 2D FSE 2D FSE 3D FFE
TR (ms) 2050 4000 10000 10.3
TE (ms) 15 92 136 3.4
TI (ms) - 2700 900
Echo train lengths 6 13 29 -
Echo space (ms) 7.5 11.5 8.5 -
Flip angle (°) 90/140 90/180 90/150 13
Matrix 320 × 320 512 × 512 256 × 256 384 × 384
FOV (mm) 200 × 200 200 × 200 200 × 200 200 × 200
Thick/gap (mm) 2.5/2.5 2.5/2.5 2.5/2.5 1/0
No. of slices 10 10 10 30
Bandwidth (Hz) 325.5 195.3 244.1 177.5
Parallel imaging factor: (SPEEDER) 2 2 1.5 1.6
(NAQ)# 1 1, 2, 5 1, 2, 5 1, 2, 5
Total scan time (s)#
  NAQ2# 164 130 122
  NAQ5# 404 310 204
*

T1WI was used in the experimental study.

**

MPRAGE was used in the clinical study.

#

NAQ1 images were used for the experimental study to generate the ground-truth images. NAQ2 and NAQ5 images were acquired in the clinical study. FLAIR, fluid-attenuated inversion recovery; NAQ, number of image acquisition.