Table 1.
Details of various software packages available for radiomic feature calculation. The listed number of citations are those that cite the initial publication introducing the platform according to PubMed (search on 30/01/2020)
Software | Year of publication | Citations | IBSI-compliant? | Free? | Open source? | Feature sets calculated | Mathematical equations documented? |
---|---|---|---|---|---|---|---|
MaZda [24] | 2009 | 366 | × | ✓ | × | Shape, intensity and texture | × |
Chang-Gung Image Texture Analysis (CGITA) [25] | 2014 | 65 | × | ✓ | ✓ | Intensity and texture | × |
IBEX [13] | 2015 | 134 | × | ✓ | ✓ | Shape, intensity and texture | ✓ |
Moddicom [26] | 2015 | 13 | × | ✓ | ✓ | Shape, intensity and texture | × |
PyRadiomics [14] | 2017 | 324 | ✓ | ✓ | ✓ | Shape, intensity and texture | ✓ |
LIFEx [15] | 2018 | 84 | ✓ | ✓ | × | Shape, intensity and texture | ✓ |
Quantitative Image Feature Engine (QIFE) [27] | 2018 | 13 | × | ✓ | ✓ | Shape, intensity and texture | × |
CERR [12] | 2018 | 25 | ✓ | ✓ | ✓ | Shape, intensity and texture | ✓ |
MITK Phenotyping [28] | 2019 | 6 | ✓ | ✓ | ✓ | Shape, intensity and texture | ✓ |
RaCat [29] | 2019 | 4 | ✓ | ✓ | ✓ | Shape, intensity and texture | × |
PORTS v.1.1 matlab software |
Not published | Not published | × | ✓ | ✓ | Intensity and texture | ✓ |
MatLab package (www.github.com/mvallieres/radiomics) | Not published | Not published | ✓ | ✓ | ✓ | Shape, intensity and texture | ✓ |
TexRad | Not published | Not published | Unknown | × | × | Unknown | Unknown |
Oncoradiomics | Not published | Not published | Unknown | × | × | Unknown | Unknown |