Skip to main content
. 2019 Dec 3;5(5):1042–1050. doi: 10.1016/j.adro.2019.11.005

Table 2.

Institutional clinical criteria for stereotactic body radiation therapy paraspinal and other metastatic tumor plans

Plan type Clinical criteria
Ideal Acceptable
Paraspinal
 PTV
 V100% (%) ≥90% ≥80%
 V95% (%) ≥95% ≥90%
Metastases
 PTV
 V100% (%) ≥98% ≥95%
Single fraction
 CTV
 D(smallest 0.035cc )(Gy) 15
 GTV
 D(smallest 0.035cc )(Gy) 15
 Cord
 Dmax (Gy) ≤14
 D0.35cc (Gy) ≤10
 Cauda
 Dmax (Gy) ≤18
 D5cc (Gy) ≤14
 Esophagus
 D2.5cc (Gy) ≤14 ≤18
 Bowel
 D5cc (Gy) ≤12
Three fractions
 Cord
 Dmax (Gy) ≤24 (13.9) ≤26 (14.5)
 D0.35cc (Gy) ≤18 (10)
 Cauda
 Dmax (Gy) ≤26 (15)
 D5cc (Gy) ≤22 (13)
 Esophagus
 Dmax (Gy) ≤27.6 ≤30 (20.4)
 D5cc (Gy) ≤16.8 ≤22
Five fractions
 Cord
 Dmax (Gy) ≤30 (17) ≤30 (18)
 D0.35cc(Gy) ≤23 (14)
 Cauda
 Dmax (Gy) ≤35 (20)
 D5cc (Gy) ≤30 (17)
 Esophagus
 Dmax (Gy) ≤32.2 ≤50 (25)
 D5cc (Gy) ≤19 ≤27.5

Abbreviations: CTV = clinical target volume; GTV = gross target volume; PTV = planning target volume.

10 Gy must not transect the entire cord contour on any axial slice.

Criteria with pertinent previous radiation therapy.