Skip to main content
. 2020 Sep 9;9(9):740. doi: 10.3390/pathogens9090740

Table 2.

Fluorescence intensity of Sytox green of L3s treated with a combined coriander oil-linalool preparation at five different concentrations compared with positive control (dead L3s), negative control (live L3s) and blank (L3s-free).

F.C. (%) H. contortus T. axei T. colubriformis T. circumcincta T. vitrinus C. oncophora Mixed Infection
2% 100 a 100 a 100 a 100 a 100 a 76.1 (8.5) b 100 a
1% 69.2 (13.4) a 100 a 91.6 (3.33) a 100 a 88.8 (6.6) a 76.1 (4.2) b 85.7 (7.1) a
0.5% 46.1 (11.5) b 88.8 (6.6) a 83.3 (8.33) a 81.8 (7.2) a 55.5 (8.8) b 73.9 (2.8) b 71.4 (1.43) b
0.25% 42.3 (11.5) b 77.7 (13.1) b 58.3 (5.2) b 72.7 (8.1) a 55.5 (5.5) b 65.2 (4.5) b 57.1 (2.49) b
0.125% 19.2 (1.9) b 44.4 (16.3) b 58.3 (1.6) b 27.2 (9.1) b 22.2 (3.3) b 28.5 (4.8) b 35.7 (7.4) b
IC50 (%) 0.58 0.14 0.104 0.18 0.21 0.20 0.23
R2 0.38 0.17 0.22 0.66 0.12 0.21 0.79
+ve control 92.3 (7.3) a 88.7 (5.4) a 83.3 (4.6) a 72.7 (9.1) a 88.8 (7.3) a 100 a 100 a
–ve control 34.6 (3.8) b 22.2 (5.7) b 33.3 (8.3) b 27.2 (7.2) b 33.3 (3.4) b 32.4 (2.7) b 34.6 (1.3) b

Data are presented as the normalized mean of fluorescence intensity (± SEM) and show the effect of treatment with coriander oil-linalool combination on the fluorescence uptake of Sytox green by dead L3s. a No statistical difference between positive control and treatments (p > 0.05). b Significant difference between positive control and treatments (p < 0.05; ANOVA followed by Tukey test). Abbreviations: F.C. = Final concentration; +ve control (positive control; L3s treated with 50% methanol); –ve control (negative control; L3s treated with PBS-Tween 2%); IC50 = inhibitory concentration 50%; R2 = nonlinear correlation.