Skip to main content
. 2020 Sep 15;10(9):1843. doi: 10.3390/nano10091843

Table 1.

Summary of the data collected in this paper. We followed the recommendation to use one decimal place more than the precision of our measurement [42]. We estimate the absolute error in our force measurement to be about 50% and in our extensibility measurement to be about 10%, given the error in the measured, experimental quantities. The high standard deviation of these values reflects the large variability across different fibers, not necessarily the error in measurements.

Value Average +/− Std. Dev. Data Points, N
Extensibility (Maximum Strain) 110 ± 60% 80
Maximum Stress 410 ± 210 MPa 86
Elastic Limit 5 ± 5% 51
Energy Loss 75 ± 10% 25
Fast Relaxation Time 1.1 ± 0.4 s 87
Slow Relaxation Time 16 ± 6 s 86
Initial Modulus, single pull (~10% strain) 1700 ± 800 MPa 9
Large strain Modulus, single pull (~100% strain) 110 ± 90 MPa 9
Total Modulus, incremental (0–25% strain) 1400 ± 990 MPa 90
Elastic Modulus, incremental (0–25% strain) 980 ± 710 MPa 90
Total Modulus, incremental (~100% strain) 430 ± 420 MPa 90
Elastic Modulus, incremental (~100% strain) 310 ± 250 MPa 90