Skip to main content
. 2020 Sep 21;13(18):4189. doi: 10.3390/ma13184189

Table 3.

Loading parameters for the testing series under investigation.

Test Series Crack Width in Cyclic Stage
(UO)
[µm]
Lower Reversal Point
(UU)
[mm]
Displacement Increment Per Cycle
(I)
[µm]
Number of Cycles
[-]
Number of Successfully Tested Specimens
Start End
R - - - - - 11
C40-NC-200 40 60 0.020 0.10 200 7
C40-MC-200 −0.010 10
C40-HC-200 −0.025 10
C40-NC-1000 0.020 0.02 1000 4
C40-MC-1000 −0.010 10
C40-HC-1000 −0.025 10
C40-NC-2000 0.020 0.01 2000 10
C40-MC-2000 −0.010 10
C40-HC-2000 −0.025 10
C100-NC-200 100 200 0.020 0.50 200 10
C100-MC-200 −0.010 10
C100-HC-200 −0.025 9
C100-NC-1000 0.020 0.10 1000 11
C100-MC-1000 −0.010 11
C100-HC-1000 −0.025 10
C100-NC-2000 0.020 0.05 2000 10
C100-MC-2000 −0.010 8
C100-HC-2000 −0.025 8