Skip to main content
. 2020 Oct 9;8(10):2325967120958007. doi: 10.1177/2325967120958007

Table 2.

Measurements for SSC and ISP/TM Structural Muscle Integrity Through SSC Diameters, Mean Muscle Attenuation, and Voxel Quantificationa

Preoperative Follow-Up
Latarjet ICBGT P Value Latarjet ICBGT P Value
SSC diameter, mm
 VD 82.6 ± 10.9 86.3 ± 9.6 .197 82.2 ± 12.0 83.5 ± 9.8 .668
 UTD 26.6 ± 3.8 27.3 ± 4.5 .521 26.0 ± 6.0 27.2 ± 4.7 .456
 LTD 30.3 ± 5.4 31.0 ± 6.1 .671 28.3 ± 5.2 30.1 ± 5.6 .249
Mean muscle attenuation, HU
 SSC (total) 57.5 ± 5.4 57.4 ± 4.9 .915 56.2 ± 7.6 56.2 ± 7.3 .997
 SSC (UMA) 58.1 ± 7.9 59.7 ± 8.8 .510 50.6 ± 9.7 54.7 ± 9.0 .124
 SSC (LMA) 59.2 ± 7.4 59.1 ± 5.7 .958 60.7 ± 12.7 58.6 ± 10.9 .515
 ISP/TM 66.9 ± 8.5 65.0 ± 9.3 .451 67.6 ± 9.3 66.5 ± 9.1 .651
Fatty muscle infiltration, %
 SSC 2.0 ± 2.9 2.4 ± 2.2 .546 5.3 ± 4.5 2.3 ± 1.7 .001b
 ISP/TM 1.7 ± 2.8 2.0 ± 2.5 .630 3 ± 3.6 1.7 ± 1.3 .064

aValues are expressed as mean ± SD. HU, Hounsfield units; ICBGT, iliac crest bone graft transfer; ISP, infraspinatus; LMA, lower muscle attenuation; LTD, lower transverse diameter; SSC, subscapularis; TM, teres minor; UMA, upper muscle attenuation; UTD, upper transverse diameter; VD, vertical diameter.