Skip to main content
. 2020 Sep 4;12(9):2023. doi: 10.3390/polym12092023

Table 2.

Wavelength shift and transmission loss sensitivity over three temperature test cycles under LPFG (D = 65 μm, Λ = 620 μm).

Cycle Wavelength
Sensitivity (nm/°C)
Transmission Loss
Sensitivity (dB/°C)
1st 0.0511 0.0437
2nd 0.0514 0.0562
3rd 0.0535 0.0439