Skip to main content
. 2020 Sep 9;9(9):2908. doi: 10.3390/jcm9092908

Table 1.

Details of studies included in the systematic review.

Reference Type of Intervention No. of Patients Treated Using 3D Prints Design Study, Level of Evidence Approach Software for 3D Model 3D Printing (Printer, Material, Time, Cost)
Bagaria et al. [13]
Year: 2011
Country: India, China
Acetabular fracture, femoral condyle fracture, calcaneal fracture 4 Case series LOE-IV 3DP model of fractured acetabulum (with indelible ink marked zones of fracture) used as template for precontouring the plate Mimics (Materialise, Leuven, Belgium) FDM process, ABS
19 euros
Battiato et al. [14]
Year: 2017
Country: Italy
Both acetabular fractures 1 Case report LOE-V 3DP of entire pelvis used for fractures reduction and then for precontouring the plates Mimics (Materialise, Leuven, Belgium) SLS process,
Polyamide PA2200,
46 h the entire development process
Belien et al. [15]
Year: 2017
Country: Belgium
Os acromiale, acromial fracture 5 Case series LOE-IV 3DP model of fractured bone after fracture reduction used as template for precontouring the plate in Vesalius (CTI, SP, Brazil), Rhinoceros 5 (Robert McNeel & Associates, Seattle, USA), Meshmixer (Autodesk, San Rafael, USA), Netfabb Pro (Autodesk, San Rafael, USA) Makerbot Replicator 2, FDM process
Brown et al. [16]
Year: 2002
Country: USA
Acetabular fracture 8 Case series LOE-IV 3DP model of the mirrored model of uninjured acetabulum for precontouring the plate Mimics (Materialise, Leuven, Belgium) Actua 2100, SLA, Wax, then mould methyl methacrylate
Chana-Rodriquez et al. [17] Year: 2016
Country: Spain
Acetabular fracture 1 Case report LOE-V 3DP model of the mirrored model of uninjured acetabulum used as template for precontouring the plate OsiriX (Pixmeo, Geneva, Switzerland), Meshlab V1.3.3 (Visual Computing Lab, Pisa, Italy), Meshmixer 2.4 (Autodesk, San Rafael, USA Da Vinci 3D printer, FDM process, ABS, 11 h, 12 euros
Chana- Rodriquez et al. [18] Year: 2018
Country: Spain
Acetabular fractures 20 Prospective case series LOE-IV 3DP model of the mirrored model of uninjured acetabulum used as template for precontouring the plate OsiriX (Pixmeo, Geneva, Switzerland), Meshmixer (Autodesk, San Rafael, USA)
Mean of 10.7 min for medical modeling
Da Vinci 3D printer, FDM process, ABS
Mean of 385 min for 3D prints manufacturing
12 euros
Chen YY et al. [19]
Year: 2018
Country: China
Rib fractures 16 Retrospective review 48 patients LOE-IV 3DP model of fractured ribs/rib (with indelible ink marked zones of fractures) used as template for precontouring the plate - UP-BOX 3D
Printer, FDM process, ABS 5–6 h for 3DP printing
Chen K et al. [20]
Year 2019
Country: China
Bicolumnar acetabular fracture 28 Retrospective analysis, 52 patients, LOE-III Virtual fracture reduction + 3DP reduced fracture model for precontouring the plate Mimics 16.0 (Materialise, Leuven, Belgium) PLA, 36 h total time (including sterilization, bending), 65 euro
Chung et al. [21]
Year: 2014
Country: S. Korea
Calcaneal fracture 1 Case report LOE-V 3DP model of contralateral uninjured calcaneus used as template for precontouring the plate Mimics (Materialise, Leuven, Belgium),
30 min modeling
Probably FDM process
3 h printing
Hao et al. [22]
Year: 2019
Country: China
Midshaft clavicle fracture 1 Case report LOE-V 3DP model of contralateral uninjured clavicle used as template for precontouring plate Mimics 17.0 (Materialise, Leuven, Belgium) DLP process
Hsu et al. [23]
Year: 2019
Country: China
Acetabular fracture 12 Retrospective study with control group LOE-III
Total of 29 patients
Virtual reduction of fracture + 3DP model of reduced fracture used as template for precontouring plate Mimics 19.0 (Materialise, Leuven, Belgium) Up Box+, FDM process
Hung et al. [24]
Year: 2019
Country: China
Pelvic ring fractures 16 Retrospective study, non-randomized with control group LOE-III
Total of 30 patients
Virtual reduction of fracture + 3DP model of reduced fracture used as template for precontouring the plate Mimics 19.0 (Materialise, Leuven, Belgium)
Up to 90 min virtual reduction for complex cases
UP BOX+ 3D printer, FDM process
Less than 24 h the entire process, 20 euros
Jeong et al. [25]
Year: 2014
Country: S. Korea
Clavicle shaft fracture 1 Case report LOE-V 3DP of contralateral clavicle used as template for precontouring the plate - $20, 3 h for 3DP, 3 h for plate bending and sterilization
Kataoka et al. [26]
Year: 2013
Country: Japan
4 cubitus varus,
1 cubitus valgus,
4 diaphyseal malunions of the forearm
9 Series of cases, LOE-Therapeutic IV Virtual planning and simulation
using contralateral normal bone as template + 3DP of repositioned bone models as template for precontouring the plate
Bone Simulator (Orthree,
Osaka, Japan)
Eden 250, Objet, Medical grade resin
Kim et al. [27]
Year: 2015
Country: S. Korea, China
Midshaft clavicle fracture 7 Series of cases (technical note) LOE-IV 3DP model of contralateral uninjured clavicle used as template for precontouring the plate Mimics (Materialise, Leuven, Belgium) Project x60 series, $100,
2–3 days the whole process CT to solid model
Li L et al. [28]
Year: 2017
Country: China
Pelvic fracture 28 Retrospective review (long-term follow up study with control group), Total of 64 patients LOE-III 3DP model of pelvis used for simulating operation and then for precontouring the plates Mimics 14.0 (Materialise, Leuven, Belgium) Yinhua Rapid Prototyping 3D printer, probably FDM process
Li YT et al. [29]
Year: 2019
Country: China
Hip dislocation combined with acetabular fracture 7 Retrospective review control group
Total of 16 patients
LOE-III
Virtual reduction by mirroring contralateral, uninjured side + 3DP model of reduced model used as template for precontouring the plate Mimics 19.0 (Materialise, Leuven, Belgium),
11 min for modeling
Up Box+ 3D printer, FDM process,
10 h for 3D printing
Maini et al. [30]
Year: 2018
Country: India
Acetabular fracture 10 Prospective randomized case control study
Total of 21 patients
LOE-II
3DP model of fractured acetabulum followed by its reduction and its use as template for precontouring the plate Mimics 8.13 (Materialise, Leuven, Belgium) Eosint P380, SLS, nylon polyamide, $15–20
Maini et al. [31]
Year: 2018
Country: India
Acetabular fracture 12 Randomized case control study
25 patients LOE-II
Virtual planning and simulation for reducing fracture followed by virtual modeling the plate (virtual plating) + 3D-printed plate model as template for precontouring the metal plate Mimics and 3-Matic (Materialise, Leuven, Belgium), Average time: 4.3 h FDM, PLA, $4
Nie et al. [32]
Year: 2018
Country: China
Pubic rami fractures 30 Consecutive case series LOE-IV Virtual planning and reduction of fracture + 3DP model of reduced fracture used as template for precontouring plate Mimics 10.01 (Materialise, Leuven, Belgium) FDM process, ABS material probably
Shon et al. [33]
Year: 2018
Country: S. Korea
Both-column acetabular fractures 5 Series of cases LOE-IV 3DP model of fractured acetabulum (with indelible ink marked fracture line) followed by reduction and fixation with glue, thus reduced model being used as template for precontouring the plate - Edison 3D printer, FDM process, PLA, 3 h total development time for the 3D print, $30
Smith et al. [34]
Year: 2018
Country: USA
Rib fractures 1 Case report LOE-V Virtual reduction using mirroring of contralateral uninjured side + 3DP model with reduced fractured and marked fracture lines used as template for precontouring plates D2P (3D Systems, Rock Hill, USA), Geomagic Freeform Plus (3D Systems, Rock Hill, USA) ProX 800 3D printer, SLA, ClearView polycarbonate-like resin
ten Berg et al. [35]
Year: 2017
Country: The Netherlands
Nonunion of scaphoid fracture 8 Series of cases (short report letter) LOE-V 3DP model of uninjured contralateral bone for plate bending Custom software (C++(Visual
Studio 2005, Microsoft, Redmond, USA), Visualization ToolKit (VTK 5.0.4, Kitware, Inc., NY, USA), Insightt ToolKit (ITK 3.6.0, Kitware, Inc., NY, USA)
Blue printer M2, Selective Heat Sintering, Thermoplastic powder
Upex et al. [36]
Year: 2017
Country: France
Acetabular fracture 1 Case report (technical note) LOE-V 3DP model of the healthy hemipelvis used as template for precontouring plate OsiriX (Pixmeo, Geneva,
Switzerland), Meshmixer (Autodesk, San Rafael, USA)
Ultimaker, FDM process, PLA, 6 euros
Van Doremalen et al. [37] Year: 2016
Country: The Netherlands
Midshaft clavicle fracture 1 Case report LOE-V 3DP model of contralateral intact clavicle for plate bending Matlab(MathWorks, Natick, USA), Meshlab (Visual Computing Lab, Pisa, Italy BQ Witbox, FDM process, PLA, 4 h total time for the whole process (modeling, 3DP, bending)
Wang et al. [38]
Year: 2018
Country: China
Humeral shaft fracture 21 Retrospective review, 46 patients, comparison 3DP model with Synbone model LOE-IV 3DP model of intact bone used as template for precontouring the plate Mimics 16.0 (Materialise, Leuven, Belgium)
3 h modeling time
Lite, RS6000, DLP process, ultraviolet curable resin
Yao et al. [39]
Year: 2019
Country: China, Australia
Calcaneal fractures 25 Case series LOE-IV 3DP model of uninjured calcaneus used as template for precontouring plate Mimics 15.0 (Materialise, Leuven, Belgium) Makerbot Replicator 3D printer
Yu et al. [40]
Year: 2015
Country: UK
Both column acetabulum fractures 2 Cases report LOE-V 3DP model of contralateral uninjured side used as template for precontouring the plate - Objet Eden 250 3D printer, SLS process, MED610 polymer
Zeng et al. [41]
Year: 2016
Country: China
Acetabular fracture 10 Series of cases LOE-IV Virtual fracture reduction + 3DP reduced fracture model for precontouring the plate Mimics 14.0 (Materialise, Leuven, Belgium) Makerbot Replicator 2, FDM process
Zhuang et al. [42]
Year: 2016
Country: China
Acetabular fractures (7 fractures anterior column, 4 anterior column with posterior hemitransverse, 1 anterior column with the pubic symphysis) 12 Case series LOE-IV 3D printed model on uninjured hemipelvis with marked fracture lines used as template for precontouring the plate - Mira ProJet 3510 3D printer, MJ process, ultraviolet curable resin