Skip to main content
. 2020 Aug 26;12(9):2420. doi: 10.3390/cancers12092420

Table 4.

Diagnostic performance of ADC-, IVIM- and DKI-derived parameters to detect RAS mutation.

AUC Sensitivity Specificity PPV NPV Accuracy Cut-off
ADC Mean 0.61 0.52 0.76 0.45 0.81 0.70 1157.41
ADC STD 0.56 0.76 0.45 0.34 0.83 0.53 166.70
MK Mean 0.80 0.72 0.85 0.85 0.69 0.79 203.90
MK STD 0.27 0.06 1.00 1.00 0.46 0.48 3218.51
MD Mean 0.80 0.84 0.73 0.54 0.92 0.77 1694.30
MD STD 0.66 0.56 0.78 0.48 0.83 0.72 377.11
S0 Mean 0.45 0.32 0.78 0.35 0.75 0.65 117.10
S0 STD 0.59 0.48 0.76 0.43 0.80 0.68 19.60
FP Mean 0.77 0.84 0.73 0.54 0.92 0.75 148.30
FP STD 0.66 0.76 0.63 0.43 0.88 0.66 79.10
DT Mean 0.56 0.44 0.81 0.46 0.79 0.71 1100.62
DT STD 0.65 0.56 0.76 0.47 0.82 0.71 258.40
DP Mean 0.65 0.76 0.58 0.40 0.87 0.63 113.60
DP STD 0.60 0.68 0.58 0.38 0.83 0.61 69.30

Note. AUC = are under curve; PPV = positive predictive value; NPV = negative predictive value. In bold are reported the significant parameters in the detection of RAS mutation.