Table 5.

Follow-up comparison of different anti-SARS-CoV-2-antibody assays.

Individual SCO Mikrogen Euroimmun
IgG ratio
Abbott Architect
Individuals tested initially POSITIVE by the Mikrogen assay
1 32.00 0.1 0.09
3 61.60 0.1 0.05
4 23.00 0.1 0.21
5 38.90 0.1 NA
6 39.20 0.1 0.05
7 18.80 0.1 NA
8 34.40 0.1 0.02
10 30.60 0.1 0.02
11 36.30 0.1 0.05
12 37.10 0.1 0.07
14 26.60 0.1 0.05
15 24.00 0.1 0.02
17 21.80 0.1 0.02
Individuals tested initially POSITIVE by the Euroimmun assay
21 73.90 2.8 1.6
22 52.70 1.3 4.87
23 24.10 0.9 1.59
Individuals tested initially EQUIVOCAL by the Mikrogen assay
25 21.80 0.1 0.07
26 21.00 0.1 0.02
27 14.40 0.2 0.21
28 11.70 0.1 0.02
30 19.60 0.1 0.31

Individual refers to the individuals presented in Table 3, NA: not available.

Mikrogen assay (equivocal: ratio ≥ 20 to >24; seropositive: ratio ≥ 24)

Euroimmun assay (equivocal: ratio ≥ 0.8 to < 1.1; seropositive: ratio ≥ 1.1)