Table 4.

The electrical conductivity of TPE with different absorbed dose.

Sample ID Dose (kGy) Electrical Conductivity, σ (S/m) Single Factor ANOVA
TPE 0 3.79 Χ 10−14 F value: 1197.551
p-value: 2.35E-13
F critical: 3.478
NC0 0 4.51 Χ 10−12
NC100 100 2.38 Χ 10−10
NC150 150 1.41 Χ 10−9
NC200 200 4.14 Χ 10−11
NC250 250 8.62 Χ 10−12