Taguchi’s L18 experimental design matrix.

Exp. Trial Levels of Process Parameters Actual Values of Process Parameters
A B C D E A B C D E
1. 1 1 1 1 1 Plain dielectric 1 30 60 30
2. 1 1 2 2 2 Plain dielectric 1 45 90 40
3. 1 1 3 3 3 Plain dielectric 1 60 120 50
4. 1 2 1 1 2 Plain dielectric 2 30 60 40
5. 1 2 2 2 3 Plain dielectric 2 45 90 50
6. 1 2 3 3 1 Plain dielectric 2 60 120 30
7. 1 3 1 2 1 Plain dielectric 4 30 90 30
8. 1 3 2 3 2 Plain dielectric 4 45 120 40
9. 1 3 3 1 3 Plain dielectric 4 60 60 50
10. 2 1 1 3 3 MWCNTs mixed dielectric 1 30 120 50
11. 2 1 2 1 1 MWCNTs mixed dielectric 1 45 60 30
12. 2 1 3 2 2 MWCNTs mixed dielectric 1 60 90 40
13. 2 2 1 2 3 MWCNTs mixed dielectric 2 30 90 50
14. 2 2 2 3 1 MWCNTs mixed dielectric 2 45 120 30
15. 2 2 3 1 2 MWCNTs mixed dielectric 2 60 60 40
16. 2 3 1 3 2 MWCNTs mixed dielectric 4 30 120 40
17. 2 3 2 1 3 MWCNTs mixed dielectric 4 45 60 50
18. 2 3 3 2 1 MWCNTs mixed dielectric 4 60 90 30