Table 4.
Exp. Trial | Levels of Process Parameters | Actual Values of Process Parameters | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
A | B | C | D | E | A | B | C | D | E | |
1. | 1 | 1 | 1 | 1 | 1 | Plain dielectric | 1 | 30 | 60 | 30 |
2. | 1 | 1 | 2 | 2 | 2 | Plain dielectric | 1 | 45 | 90 | 40 |
3. | 1 | 1 | 3 | 3 | 3 | Plain dielectric | 1 | 60 | 120 | 50 |
4. | 1 | 2 | 1 | 1 | 2 | Plain dielectric | 2 | 30 | 60 | 40 |
5. | 1 | 2 | 2 | 2 | 3 | Plain dielectric | 2 | 45 | 90 | 50 |
6. | 1 | 2 | 3 | 3 | 1 | Plain dielectric | 2 | 60 | 120 | 30 |
7. | 1 | 3 | 1 | 2 | 1 | Plain dielectric | 4 | 30 | 90 | 30 |
8. | 1 | 3 | 2 | 3 | 2 | Plain dielectric | 4 | 45 | 120 | 40 |
9. | 1 | 3 | 3 | 1 | 3 | Plain dielectric | 4 | 60 | 60 | 50 |
10. | 2 | 1 | 1 | 3 | 3 | MWCNTs mixed dielectric | 1 | 30 | 120 | 50 |
11. | 2 | 1 | 2 | 1 | 1 | MWCNTs mixed dielectric | 1 | 45 | 60 | 30 |
12. | 2 | 1 | 3 | 2 | 2 | MWCNTs mixed dielectric | 1 | 60 | 90 | 40 |
13. | 2 | 2 | 1 | 2 | 3 | MWCNTs mixed dielectric | 2 | 30 | 90 | 50 |
14. | 2 | 2 | 2 | 3 | 1 | MWCNTs mixed dielectric | 2 | 45 | 120 | 30 |
15. | 2 | 2 | 3 | 1 | 2 | MWCNTs mixed dielectric | 2 | 60 | 60 | 40 |
16. | 2 | 3 | 1 | 3 | 2 | MWCNTs mixed dielectric | 4 | 30 | 120 | 40 |
17. | 2 | 3 | 2 | 1 | 3 | MWCNTs mixed dielectric | 4 | 45 | 60 | 50 |
18. | 2 | 3 | 3 | 2 | 1 | MWCNTs mixed dielectric | 4 | 60 | 90 | 30 |