Skip to main content
. Author manuscript; available in PMC: 2021 Nov 1.
Published in final edited form as: Magn Reson Imaging. 2020 Sep 1;73:152–162. doi: 10.1016/j.mri.2020.08.013

Table 1:

Reconstruction time analysis of MS-ResNet and Gadgetron nonlinear conjugate gradient (NLCG) algorithm. Non-uniform Fast Fourier transform (NUFFT) is the major computation for non-Cartesian k-space data reconstruction using NLCG. Oversampling ratio is a critical factor of NUFFT that can be used to trade accuracy for computational time reductions as shown in the table.

Time (ms/slice)
Data Dimensionsa Gadgetron NLCG MS-ResNet
os = 1.2 os = 2.0 os = 1.2 os = 2.0
T2 knee 320,512,15,8 6601.4 9212.5 82.3 95.3
T2 brain 320,256,16,16 9697.2 14438.3 102.2 125.7
T1 brain 320,512,16,32 18740.0 25914.0 158.8 194.3
T1 abdomen 384,512,20,32 29181.8 73756.3 265.7 486.4
a

From left to right, the values denote number of readout points, number of total radial lines, number of coils, and number of contrasts.