Skip to main content
. 2020 Oct 22;68:104321. doi: 10.1016/j.jlp.2020.104321

Table A-3.

Automatically created extended HAZOP worksheet for the deviations ‘high temperature’ and ‘low temperature’

Pos. Unit Id. Substance Deviation Super cause Cause Effect Consequence Safeguard
35 StorageTank-Unit T-301 Hexane High-Temperature MechanicalDamage HeatInputBy-Recirculation-Pump AbnormalEvaporation ExceedingAllowable-Pressure PressureReliefValve
36 StorageTank-Unit T-301 Hexane High-Temperature MechanicalDamage HeatInputBy-Recirculation-Pump ExceedingFlashPoint IgnitionSource-Assessment
37 StorageTank-Unit T-301 Hexane High-Temperature AbnormalHotIntake, ExternalFire,
SolarRadiation
AbnormalHeat-Input AbnormalEvaporation ExceedingAllowable-Pressure PressureReliefValve
38 StorageTank-Unit T-301 Hexane High-Temperature AbnormalHotIntake, ExternalFire,
SolarRadiation
AbnormalHeat-Input ExceedingFlashPoint IgnitionSource-Assessment
39 StorageTank-Unit T-301 Hexane Low-Temperature Ambient-Temperature-Change BrittleFracture LossOfPrimaryContainment, Fire CollectingBasin
40 StorageTank-Unit T-301 Hexane Low-Temperature Ambient-Temperature-Change BrittleFracture LossOfPrimaryContainment, FormationOfExAtmosphere, Explosion CollectingBasin,
DefineExProtectionZone