Skip to main content
. 2020 Oct 23;66(6):1085–1104. doi: 10.1007/s00267-020-01375-5

Table 6.

Data and calculation of the quantitative environment-safety-related criteria for (a) solid waste treatment and (b) wastewater treatment

(a) SW1 SW2 SW3 SW4 SW5
Energy consumption (CES1) in Kj 3.24E + 03 5.12E + 03 1.13E + 03 5.32E + 03 5.82E + 03
Disinfection efficiency (CES2) in % 85.48% 81.12% 91.11% 92.42% 92.15%
Toxic gas mitigation (CES3) in kg CO2 Eq 1.33E + 03 3.12E + 03 1.54E + 03 2.42E + 03 1.99E + 03
Aquatic ecotoxicity (CES5) in CTUe 1.01E + 04 2.21E + 04 1.74E + 04 3.85E + 04 1.59E + 04
(b) WW1 WW2 WW3 WW4 WW5
Energy consumption (CES1) in Kj 6.18E + 02 6.22E + 02 6.35E + 02 1.13E + 02 8.58E + 02
Disinfection efficiency (CES2) in % 95.33% 90.19% 92.69% 75.13% 90.48%
Toxic gas mitigation (CES3) in kg CO2 Eq 8.82E + 03 8.74E + 03 8.91E + 03 1.10E + 02 3.18E + 03
Aquatic ecotoxicity (CES5) in CTUe 6.15E + 03 6.94E + 05 6.33E + 05 3.54E + 04 5.11E + 03