Skip to main content
. 2020 Sep 24;20(19):5474. doi: 10.3390/s20195474

Table 2.

Real-time results for three subjects controlling the virtual home automation system.

Subjects Correct Command Response Time
Neye-blink Ndouble-blink NSSVEP Teye-blink (s) Tdouble-blink (s) TSSVEP (s)
S1 16/16 1/2 14/16 1.25 1.652 1.754
S2 15/16 2/2 15/16 1.425 1.576 1.953
S3 16/16 2/2 14/16 1.274 1.597 1.731
Total 47/48 5/6 43/48 1.316 1.608 1.813
Std. 0.036 0.289 0.036 0.095 0.039 0.122