Skip to main content
. 2020 Sep 24;20(19):5474. doi: 10.3390/s20195474

Table 3.

Related works regarding the hybrid EEG and eye blink BCI system.

Study Type Category Commands Channel Accuracy (%) Time (s) ITR (bits/min)
Wang et al. [44] Real P-300 + Eye blink + MI 8 17 91.25 4 N/A
Wang et al. [45] Virtual SSVEP + Eye blink 12 4 40–100 0–20 N/A
Park et al. [46] Virtual SSVEP + AR + Eye blink 16 32 92.8 20 37.4
Duan et al. [47] Real MI + SSVEP + Eye blink 6 12 86.5 48 1.69
Malik et al. [30] Virtual SSVEP + Eye tracking 48 8 90.35 1 184.06
He et al. [29] Virtual MI + Eye blink N/A 32 96.02 6.16 45.97
Our study Virtual SSVEP + Eye blink 38 1 96.92 2 146.67