Skip to main content
. 2020 Oct 19;13:3669–3677. doi: 10.2147/IDR.S250315

Table 6.

Comparison Between Antimicrobial Susceptibility by Vitek and the Detected Resistant Genes by PCR for the 19 Isolated S. pneumonia

Molecular Detection of Resistant Genes Vitek (MIC)
Penicillin Erythromycin
(S) (R) (S) (R)
Positive PBP-2b 15 2 - -
Negative PBP-2b 2 0
Negative Erythromycin Gene 15 0
Positive Erythromycin Gene 2 2