. 2020 Sep 8;11(10):5458–5469. doi: 10.1364/BOE.403086

Fig. 4.

Fig. 4.

(a) Principle of the closed loop control system with PID controller. (b) Variation of optical intensity toward driven current. (c) Electrical signals in the time domain.