Skip to main content
. 2020 Oct 15;25(20):4741. doi: 10.3390/molecules25204741

Table 1.

The related thermal data of RPUF and its composites under air condition.

Sample No. T−5 (°C) T−50 (°C) Tmax (°C) Residues at 750 °C
(wt.%)
Step 1 Step 2
RPUF-1 260.8 383.4 297.4 604.6 1.41
RPUF-2 220.4 504.6 310.2 590.3 8.74
RPUF-3 240.6 505.4 294.1 556.5 5.32
RPUF-4 245.1 437.9 294.4 564.4 4.18
RPUF-5 236.6 497.7 294.3 550.6 5.65
RPUF-6 236.2 486.4 297.2 565.4 4.33

Notes: T−5 means the temperature at 5% weight loss; T−50 denotes the temperature at 50% weight loss; Tmax indicates the temperature corresponding to the maximum weight loss rate.