Skip to main content
. 2020 Oct 24;2(5):e511–e515. doi: 10.1016/j.asmr.2020.05.015

Table 1.

Percent Change in Graft Dimensions Following Testing

Native 95% CI Suture-Reinforced 95% CI P Value
Medial width –21.05 ± 2.94% –18.17% to – 23.93% –5.80 ± 4.17% –1.71% to – 9.89% .001
Lateral width –19.29 ± 1.64% –17.68% to –20.90% –5.45 ± 3.70% –1.82% to –9.08% <.001
Anterior length +14.50 ± 3.13% +11.43% to +17.57% +6.36 ± 3.50% +2.93% to +9.79% .013
Posterior length +13.68 ± 2.64% +11.09% to +16.27% +6.00 ± 1.53% +4.50% to +7.50% .002
Medial thickness –17.93 ± 3.80% –14.21% to – 21.65% –4.38 ± 5.12% 0.00% to –9.40% .005
Central thickness –16.11 ± 3.19% –12.98% to – 19.24% –7.03 ± 5.28% –1.86% to –12.20% .026
Lateral thickness –20.80 ± 2.54% –18.31% to –23.29% –4.55 ± 4.55% –0.09% to –9.01% <.001

CI, confidence interval.

Values demonstrate average ± standard deviation; (+) values indicate material lengthening and (–) values indicate material shrinkage.