TABLE 2.

Magnetic resonance imaging measurement parameters

Resolution in mm3, matrix size TR in ms TE in ms TI in ms FA in ° BW in Hz/px GRAPPA (factor/ref. lines) Partial Fourier (slice, phase) Acquisition time min:sec
ME‐GRE 0.47 × 0.47 × 0.47 38 10.5, 21, 31.5 12 140 2/36 6/8, 7/8 18:09
464 × 348 × 192
RESOLVE 1.2 × 1.2 × 2.4 2700 59, 99 180 631 2/68 23:55
176 × 142 × 14
ME‐TSE 0.49 × 0.49 × 2.0 7400 15, 88, 161,235 120 130 3/27 13:21
448 × 336 × 30
MP2RAGE 0.69 × 0.69 × 0.69 5000 4.01 900, 2750 4, 5 240 3/43 6/8, 7/8 8:08
320 × 240 × 192
Turbo flash (B1) 1.15 × 1.15 × 4.0 3000 2.36 7 490 1:32
192 × 144 × 15

Abbreviations: BW, bandwidth; GRAPPA, generalized autocalibrating partially parallel acquisitions; Hz, Hertz; ME‐GRE, multi‐echo gradient echo; ME‐TSE, multi‐echo turbo spin echo; min:sec, minutes:seconds; MR2RAGE, magnetization prepared 2 rapid acquisition gradient echo; ms, milliseconds; px, pixel; ref., reference; RESOLVE, readout segmentation of long variable echo‐trains;TE, echo time; TI, inversion time; TR, repetition time.