Test Results of binary classifiers on CT data.

Precision Recall F1 score Accuracy AUC
COVID-CT
ResNet-18 0.57 0.77 0.65 0.61 0.61
ResNet-50 0.87 0.76 0.81 0.83 0.83
DenseNet-169 0.8 0.67 0.73 0.76 0.76
WideResNet-50 0.85 0.80 0.82 0.83 0.83
DenseNet-121+
0.67
0.04
0.08
0.53
0.51
COVID-19 CT & Radiograph Image Data Stock
ResNet-18 0.86 0.71 0.78 0.74 0.75
ResNet-50 0.73 0.59 0.65 0.59 0.59
DenseNet-169 0.78 0.72 0.75 0.69 0.67
WideResNet-50 0.77 0.99 0.87 0.81 0.72
DenseNet-121+ 0.69 0.67 0.68 0.59 0.55