Table 1. Corrosion Parameters of Steel in 1.0 M HCl with Different Concentrations of Inhibitors at Different Temperatures.

    DPTU
PPTU
temperature (°C) concentration (M) i H (%) i H (%)
30   0.90   0.90  
  2.0 × 10–4 0.06 93.1 0.03 97.2
  1.0 × 10–4 0.08 91.5 0.03 96.6
  5.0 × 10–5 0.09 89.9 0.05 94.1
  1.0 × 10–5 0.14 84.9 0.07 92.6
40   1.01   1.01  
  2.0 × 10–4 0.16 84.0 0.09 90.7
  1.0 × 10–4 0.20 80.3 0.10 89.8
  5.0 × 10–5 0.21 78.8 0.12 87.9
  1.0 × 10–5 0.24 76.1 0.15 84.8
50   4.10   4.10  
  2.0 × 10–4 1.40 65.8 1.23 70.0
  1.0 × 10–4 1.54 62.5 1.28 68.9
  5.0 × 10–5 1.60 61.0 1.35 67.1
  1.0 × 10–5 1.90 53.7 1.42 65.4
60   7.35   7.35  
  2.0 × 10–4 3.98 45.8 3.21 56.3
  1.0 × 10–4 4.25 42.2 3.27 55.6
  5.0 × 10–5 4.44 39.6 3.59 51.2
  1.0 × 10–5 5.03 31.6 3.62 50.7