Table 2.

Multiparametric MRI sequence parameters

Sequence parameter T2 TSE, mean (n = 72) ADC, mean (n = 73) DCE, mean (n = 68)
TR (ms) 7511.1 3395.9 5.08
TE (ms) 104.3 59.8 1.8
Averages 2.3 7.9 1.0
Flip angle (°) 157.0 90.0 13.5
FOV (mm2) 202.8 × 202.8 94.8 × 203.2 257.9 × 259.0
Matrix (px2) 297.2 × 345.9 52.9 × 149.0 153.1 × 192.0
Bandwidth (Hz) 202.0 1203.7 260.0
Slice thickness (mm) 3.1 3.0 3.5
Orientation transversal transversal transversal
b0_1000 (n) 64
b50_1000 (n) 9

Sequence parameter for all patients included into the study (N = 73). ADC, apparent diffusion coefficient; DCE, dynamic contrast enhanced; FOV, field of view; n, absolute number; TE, echo time; TR, repetition time; TSE, turbo-spin-echo