Skip to main content
. 2020 Sep 26;9(10):791. doi: 10.3390/pathogens9100791

Table 3.

Analytical sensitivity and efficiency of developed TaqMan® qPCRs.

PCR Name Specificity Efficiency with Cloned PCR Products Efficiency Clinical DNA Detection Limit (Copy Number/µL at Cq) with Cloned PCR Products Detection Limit in Cq with Clinical DNA
G1_3_qPCR (single-plex) E. granulosus s.s. (G1, G3) 100.7% (R2 = 0.99, slope = −3.34) 96.3% (R2 = 0.99, slope = −3.41) 0.8/µL at Cq 36 (± 0.9) 38.24 (± 0.1)
G4_qPCR (single-plex) E. equinus (G4) 106.7% (R2 = 0.99, slope = −3.32) 93.7% (R2 = 0.99, slope = −3.48) 0.6/µL at Cq 39 (± 0.6) 38 (± 1)
G5_G10_qPCR (duplex) E. ortleppi (G5) 100.7% (R2 = 0.99, slope = −3.34) 97.3% (R2 = 0.99, slope = −3.39) 1.4/µL at Cq 36 (± 0.7) 37 (± 0.4)
G5_G10_qPCR (duplex) E. canadensis (G6–8, G10) 101.6% (R2 = 0.99, slope = −3.28) 99.9% (R2 = 0.99, slope = −3.33) 1.4/µL at Cq 36 (± 0.8) 38.6 (± 0.17)