Skip to main content
. 2020 Oct 10;20(20):5743. doi: 10.3390/s20205743

Table 2.

Recent reports on g-C3N4-based sensors for organic pollutants.

Analyte Method Linear Range (nM) LOD (nM) Materials Ref
4-NP LSV 1600–50,000 1 000 BSO–gCN [68]
4-NP DPV 3.3–313 0.075 OX-g-C3N4 [69]
TBBPA DPV 1–30 0.4 PDDC–g-C3N4 [70]
BPA PEC 35–280 12 Cu/g-C3N4 [71]
BPA ECL 0.001–1 0.00003 C–g-C3N4 [72]
PCP ECL 10−8–10−4 10−8 g-C3N4/graphene [74]
HQ CV 1000–320,000 300 AuNPs@g-C3N4 [75]
4-NT CV 1000–10,000 100 ZnO/g-C3N4 [76]

BSO–gCN—barium stannate-graphitic carbon nitride; OX-g-C3N4—oxidized graphitic carbon nitride; PDDC–g-C3N4—poly(diallyl dimethylammonium chloride)-graphitic carbon nitride; ECL—electrochemiluminescence; C–g-C3N4—carboxylated graphitic carbon nitride; HQ—hydroquinone; CC—catechol; 4-NT-4—nitrotoluene.