Items of the motor-cognitive testing battery.

Test Item Set-Up Task Outcome
Reaction UE Stance in front of table with one sensor. Palm of dominant hand besides sensor. Deactivate light with DH when flashing (20 lights). Mean RT [s]
Reaction LE One sensor on ground in front of standing participant. Deactivate light with DF when flashing (20 lights). Mean RT [s]
Choice-Reaction UE Stance in front of table with 8 sensors arranged semicircular and equidistantly. Deactivate randomly flashing lights with both hands (45 s). Mean RT [s]
Choice-Reaction LE 8 sensors arranged semicircular and equidistantly in front of standing participant. Deactivate randomly flashing with both feet (45 s). Mean RT [s]
Stop-signal UE Stance in front of table with one sensor. Side of dominant hand positioned next to sensor. Deactivate light with DH when flashing dark blue (go, n = 50 lights), but not when light blue (no-go, n = 10 lights). Mean RT [s], Errors [n]
Stop-signal LE One sensor positioned on ground lateral to dominant leg of standing participant. Deactivate light with DF when flashing dark blue (go, n = 42 lights), but not when light blue (no-go, n = 8 lights). Mean RT [s], Errors [n]
Memory Span Sensors (3 to 8, starting with 3, from there increasing by one) flexibly arranged on table. Arrange sensors in order of flashing. Two trials per light count. Test ends if both are failed for the first time. Time needed [s], sum score (pts.)
Reactive Agility A 8 sensors attached to the top of 8 maze-like arranged cones. Out of two flashing lights, deactivate partials (outer ring only), ignore completes (center and ring). 24 light pairs. Time needed [s]
Reactive Agility B 8 sensors attached to the top of 8 maze-like arranged cones. Alternatingly deactivate completely and partially lighting sensors (two lighting at a time as in part A). 24 light pairs. Time needed [s]
Run-Decide Three sensors attached to wall at head level (two lateral, one central). Participant at 7.5 m distance from wall. Run towards wall (4 m/s). At 3.5 m distance, cut to deactivate lateral sensors (first green light, than red light). If central sensor lights, reverse order of deactivation (10 runs, 4 with center light). Time needed to deactivate first lateral sensor [s], errors [n]

For more details and illustration of the MC tests, please see Wilke et al. [11] UE = upper extremity, LW = lower extremity, DH = dominant hand, DF = dominant foot, s = seconds, pts. = points.