Table 4.
Classification of Gloup products according to IDDSI testing methods when poured from the bottle, measured at room (24 °C) or fridge temperature (4 °C). Flow test validity (for fluids at all levels): smooth fluids are valid to be tested using the Flow test, while fluids that contain gristle, bone, husks, shell, fibres or lumps are not valid to be tested. Flow test (for fluids at all levels): the volume of fluid remaining in the syringe after 10 s. Fork Drip test (for fluids at level 3 and 4 in the Flow test): fluid drip and flow manner through fork prongs. Spoon Tilt test (for fluids at level 4 in the Fork Drip test): ability of fluid to hold its shape on the spoon and slide off easily when spoon is tilted.
Lubricants | Flow Test Validity | Flow Test # | Fork Drip Test * | Spoon Tilt Test ^ | Final IDDSI Classification | ||||
---|---|---|---|---|---|---|---|---|---|
Texture | Interpretation | Volume Remaining (mL) | Interpretation (IDDSI classification) | Flow/Drip/No Drip | Interpretation(IDDSI Classification) | Pass/Fail | Interpretation (IDDSI Classification) | ||
Room temperature | |||||||||
Gloup Original straw/ban | Smooth | Valid | 9.9 | 3 | No drip | 4 | Pass | 4 | 4 |
Gloup Sugar Free cherry | Smooth | Valid | 9.9 | 3 | No drip | 4 | Pass | 4 | 4 |
Gloup Low Sugar raspberry | Smooth | Valid | 9.9 | 3 | No drip | 4 | Pass | 4 | 4 |
Gloup Original orange | Smooth | Valid | No flow | 4 | No drip | 4 | Pass | 4 | 4 |
Gloup Forte | Smooth | Valid | No flow | 4 | No drip | 4 | Pass | 4 | 4 |
Fridge temperature | |||||||||
Gloup Original straw/ban | Smooth | Valid | No flow | 4 | No drip | 4 | Pass | 4 | 4 |
Gloup Sugar Free cherry | Smooth | Valid | No flow | 4 | No drip | 4 | Pass | 4 | 4 |
Gloup Low Sugar raspberry | Smooth | Valid | No flow | 4 | No drip | 4 | Pass | 4 | 4 |
Gloup Original orange | Smooth | Valid | No flow | 4 | No drip | 4 | Pass | 4 | 4 |
Gloup Forte | Smooth | Valid | No flow | 4 | No drip | 4 | Pass | 4 | 4 |
- Test is not applicable. # Level 3: the amount remained after 10 s is no less than 8 mL, level 4: no flow. * Level < 3: flows continuously through the fork prongs. Level 3: the sample drips in slow dollops through the fork prongs. Level 4: the sample mounds above the fork. ^ Pass: contents easily slide off spoon. Fail: contents are firm and sticky.